林华, 陈洁晶, 陈怀周, 等. Luminex技术监测抗HLA抗体对肾移植受者预后的影响[J]. 器官移植, 2016, 7(5): 386-389. DOI: 10.3969/j.issn.1674-7445.2016.05.011
引用本文: 林华, 陈洁晶, 陈怀周, 等. Luminex技术监测抗HLA抗体对肾移植受者预后的影响[J]. 器官移植, 2016, 7(5): 386-389. DOI: 10.3969/j.issn.1674-7445.2016.05.011
Lin Hua, Chen Jiejing, Chen Huaizhou, et al. Effect of anti-HLA antibody detected by Luminex testing on clinical prognosis of renal transplantation recipients[J]. ORGAN TRANSPLANTATION, 2016, 7(5): 386-389. DOI: 10.3969/j.issn.1674-7445.2016.05.011
Citation: Lin Hua, Chen Jiejing, Chen Huaizhou, et al. Effect of anti-HLA antibody detected by Luminex testing on clinical prognosis of renal transplantation recipients[J]. ORGAN TRANSPLANTATION, 2016, 7(5): 386-389. DOI: 10.3969/j.issn.1674-7445.2016.05.011

Luminex技术监测抗HLA抗体对肾移植受者预后的影响

Effect of anti-HLA antibody detected by Luminex testing on clinical prognosis of renal transplantation recipients

  • 摘要:
      目的  探讨Luminex技术检测受者体内抗人类白细胞抗原(HLA)抗体水平在预测肾移植受者预后的价值。
      方法  选取2013年6月至2015年11月在解放军第181医院拟行肾移植患者1 105例(其中354例成功接受肾移植手术),收集肾移植术前、术后血清标本共1 923例次。采用Luminex技术检测术前和术后的抗HLA抗体的阳性率和抗体荧光强度,同时并对移植受者进行移植肾功能检测。
      结果  术前抗HLA抗体阳性血清样本占总数的51.0%(546/1 071),其中抗HLA Ⅰ类抗体阳性占26.0%(279/1 071),抗HLA Ⅱ类抗体阳性占24.9%(267/1 071),其中抗HLA抗体Ⅰ、Ⅱ类均为阳性占11.4%(122/1 071)。354例肾移植患者中,术后出现抗HLA抗体者占17%(59/354),其中单独抗HLA Ⅰ类抗体阳性者25例(术后新发阳性4例),单独抗HLA Ⅱ类抗体阳性者占15例(术后新发阳性1例),两者皆阳性者19例(术后新发阳性4例)。随访期间,术后抗HLA Ⅰ类、Ⅱ类及两种抗体均阳性者出现移植肾功能异常者分别为13例、5例和11例,其中术后抗体新发阳性者均出现移植肾功能异常。
      结论  Luminex技术可动态监测肾移植术后受者抗HLA抗体水平,而抗HLA抗体阳性对预测肾移植受者预后有重要的价值。

     

    Abstract:
      Objective  To investigate the value of anti-human leukocyte antigen (HLA) antibody level detected by Luminex testing in predicting clinical prognosis of renal transplantation recipients.
      Methods  A total of 1 105 patients scheduled to undergo renal transplantation (354 successfully undergoing renal transplantation) in the 181st Hospital of Peoples Liberation Army from June 2013 to November 2015 were selected. The serum samples were collected from 1 923 cases before and after renal transplantation. The positive rate and fluorescent intensity of anti-HLA antibody were detected by Luminex testing before and after renal transplantation. The renal function of recipients was also evaluated after renal transplantation.
      Results  Prior to renal transplantation, 51.0% (546/1 071) of serum samples were positive for anti-HLA antibody, including 26.0% (279/1 071) positive for anti-HLA Ⅰ antibody, 24.9% (267/1 071) positive for anti-HLA Ⅱ antibody and 11.4% (122/1 071) positive for both anti-HLA Ⅰ and anti-HLA Ⅱ antibodies. Among 354 patients undergoing renal transplantation, 59 (17%) were positive for anti-HLA antibody after renal transplantation, including 25 (4 newly positive after surgery) positive for anti-HLA Ⅰ antibody, 15 (1 newly positive after surgery) positive for anti-HLA Ⅱ antibody and 19 (4 newly positive after surgery) positive for both anti-HLA Ⅰ and anti-HLA Ⅱ antibodies. During subsequent follow-up, 13 patients positive for anti-HLA Ⅰ antibody, 5 positive for anti-HLA Ⅱ antibody and 11 positive for both anti-HLA Ⅰ and anti-HLA Ⅱ antibodies developed transplant kidney dysfunction. All patients newly positive for anti-HLA antibody after renal transplantation presented with transplant kidney dysfunction.
      Conclusions  Luminex testing can perform dynamic detection of the positive rate of anti-HLA antibody, which is important in predicting clinical prognosis of recipients after renal transplantation.

     

/

返回文章