  • Publish Date: 2014-05-15
  •   Objective   To explore the clinical effect of mechanical perfusion for preserving kidney.   Methods   From May to October 2013, 36 donors' kidneys were preserved by mechanical perfusion in the Department of Kidney in the 181st Hospital of Chinese People's Liberation Army. The donors' kidneys were preserved, transported and perfused by the LKT-100 type Lifeport organ transporter and special software. General condition of patients and the relationship between resistance coefficient, flow velocity and occurrence of delayed graft function(DGF) were analyzed.   Results   None of 36 recipients had graft loss. Thirty cases' (83%) renal function recovered well without DGF. Six cases developed DGF and returned to normal gradually after 3-18 days postoperative treatment. After mechanical renal perfusion for 1 h, 28 recipients with kidneys' resistance coefficient≤0.3 mmHg/(ml·min)hadn't developed DGF after transplantation. Among 8 recipients with kidneys' resistance coefficient>0.3 mmHg/(ml·min), 6 recipients developed DGF. Eight recipients with kidneys' flow velocity>100 ml/min hadn't developed DGF. Among 21 recipients with kidneys' flow velocity 60-100 ml/min, 1 case developed DGF. In 7 recipients with kidneys' flow velocity < 60 ml/min, 5 cases developed DGF.   Conclusions   Mechanical perfusion for preserving kidney can improve graft quality and reduce the incidence of DGF in recipients.

     

  • loading
  • [1]
    李刚,张洪宪,赵磊,等. 边缘活体肾移植[J].器官移植,2013,4(3):123-126. http://www.organtranspl.com/browse/detail/qkid/29/id/277.html

    Li G, Zhang HX, Zhao L, et al. Marginal living donor renal transplantation[J]. Organ Transplant,2013,4(3):123-126. http://www.organtranspl.com/browse/detail/qkid/29/id/277.html
    [2]
    Hammerman MR. Classic and current opinion in embryonic organ transplantation[J]. Curr Opin Organ Transplant,2014,19(2):133-139. doi: 10.1097/MOT.0000000000000054
    [3]
    于立新,夏仁飞,邓文锋, 等.肾移植中应用抗胸腺淋巴细胞球蛋白诱导治疗的15年临床经验总结[J].中华器官移植杂志,2013,34(8):466-468. http://cn.bing.com/academic/search?q=2013%e4%b8%ad%e5%9b%bd%e5%99%a8%e5%ae%98%e7%a7%bb%e6%a4%8d%e5%a4%a7%e4%bc%9a%e8%ae%ba%e6%96%87%e6%b1%87%e7%bc%96&FORM=AJOUR

    Yu LX, Xia RF, Deng WF, et al. 15-year clinical experience in ATG induction after renal transplantation[J]. Chin Organ Transplant,2013,34(8):466-468. http://cn.bing.com/academic/search?q=2013%e4%b8%ad%e5%9b%bd%e5%99%a8%e5%ae%98%e7%a7%bb%e6%a4%8d%e5%a4%a7%e4%bc%9a%e8%ae%ba%e6%96%87%e6%b1%87%e7%bc%96&FORM=AJOUR
    [4]
    Devos JM, Gaber AO, Teeter LD, et al. Intermediate-term graft loss after renal transplantation is associated with both donor-specific antibody and acute rejection[J]. Transplantation,2014,97(5):534-540. doi: 10.1097/01.TP.0000438196.30790.66
    [5]
    Zaza G, Rascio F, Pontrelli P, et al. Karyopherins: potential biological elements involved in the delayed graft function in renal transplant recipients[J].BMC Med Genomics,2014,7(1):14. doi: 10.1186/1755-8794-7-14
    [6]
    Aktaş A. Transplanted Kidney Function Evaluation[J]. Semin Nucl Med,2014,44(2):129-145. doi: 10.1053/j.semnuclmed.2013.10.005
    [7]
    钟自彪,叶啟发,范林,等.应用机械灌注保存心脏死亡器官捐献供肾的效果分析[J/CD].中华移植杂志: 电子版,2013,7(1):1-5.

    Zhong ZB, Ye QF, Fan L, et al. Effect of machine perfusion on preservation of kidneys from donors of cardiac death[J/CD]. Chin J Transplant: Electronic Edition,2013,7(1):1-5.
    [8]
    Catena F, Coccolini F, Montori G, et al. Kidney preservation: review of present and future perspective[J]. Transplant Proc,2013,45(9):3170-3177. doi: 10.1016/j.transproceed.2013.02.145
    [9]
    Voigt MR, DeLario GT. Perspectives on abdominal organ preservation solutions: a comparative literature review[J]. Prog Transplant,2013,23(4):383-391. doi: 10.7182/pit2013100
    [10]
    Wszola M, Kwiatkowski A, Domagala P, et al. Preservation of kidneys by machine perfusion influences gene expression and may limit ischemia/reperfusion injury[J]. Prog Transplant,2014,24(1):19-26. doi: 10.7182/pit2014384
    [11]
    Schold JD, Kaplan B, Howard RJ, et al. Are we frozen in time? analysis of the utilization and efficacy of pulsatile perfusion in renal transplantation[J]. Am J Transplant,2005,5(7):1681-1688. doi: 10.1111/ajt.2005.5.issue-7
    [12]
    Moers C, Pirenne J, Paul A, et al. Machine perfusion or cold storage in deceased-donor kidney transplantation[J]. N Engl J Med,2012,366(8):770-771. doi: 10.1056/NEJMc1111038
    [13]
    Cannon RM, Brock GN, Garrison RN, et al. To pump or not to pump: a comparison of machine perfusion vs cold storage for deceased donor kidney transplantation[J]. J Am Coll Surg,2013,216(4):625-634. doi: 10.1016/j.jamcollsurg.2012.12.025
    [14]
    薛武军,田普训,项和立,等.心脏死亡器官捐献供肾移植单中心60例经验总结[J].中华器官移植杂志,2013,34(7):387-391.

    Xue WJ, Tian PX, Xiang HL, et al. Donation after cardiac death (DCD) donor renal transplantation: a single center 60 cases of DCD experience[J]. Chin J Organ Transplant,2013,34(7):387-391.
    [15]
    Tsoulfas G. Commentary on: lipid peroxidation in machine perfusion of older donor kidneys[J]. J Surg Res,2013,185(1):e43-e44. doi: 10.1016/j.jss.2012.07.009
    [16]
    Tanriover B, Mohan S, Cohen DJ, et al. Kidneys at higher risk of discard: expanding the role of dual kidney transplantation[J]. Am J Transplant,2014,14(2):404-415. doi: 10.1111/ajt.12553
    [17]
    Parsons RF, Guarrera JV. Preservation solutions for static cold storage of abdominal allografts: which is best?[J]. Curr Opin Organ Transplant,2014,19(2):100-107. doi: 10.1097/MOT.0000000000000063
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (175) PDF downloads(7) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return