Technical operation specification for perfusion, preservation and repair of donor kidney (2019 edition)
-
摘要: 为了进一步规范供肾灌注、保存和修复的技术操作, 中华医学会器官移植学分会组织器官移植学专家从器官保存液的选择、灌注和保存方法的原则及规范、肾脏体外修复等方面, 制订本规范。
-
[1] KATHS JM, PAUL A, ROBINSON LA, et al. Ex vivo machine perfusion for renal graft preservation[J]. Transplant Rev (Orlando), 2018, 32(1):1-9. DOI: 10.1016/j.trre.2017.04.002. [2] JOCHMANS I, AKHTAR MZ, NASRALLA D, et al. Past, present, and future of dynamic kidney and liver preservation and resuscitation[J]. Am J Transplant, 2016, 16(9):2545-2555. DOI: 10.1111/ajt.13778. [3] MINOR T, SUTSCHET K, WITZKE O, et al. Prediction of renal function upon reperfusion by ex situ controlled oxygenated rewarming[J]. Eur J Clin Invest, 2016, 46(12):1024-1030. DOI: 10.1111/eci.12687. [4] DE DEKEN J, KOCABAYOGLU P, MOERS C. Hypothermic machine perfusion in kidney transplantation[J].Curr Opin Organ Transplant, 2016, 21(3):294-300. DOI: 10.1097/MOT.0000000000000306. [5] SUI M, ZHANG L, YANG J, et al. A new HC-A Ⅱ solution for kidney preservation: a multi-center randomized controlled trial in China[J]. Ann Transplant, 2014, 19:614-620. DOI: 10.12659/AOT.892250. [6] JIA JJ, LI JH, JIANG L, et al. Liver protection strategies in liver transplantation[J]. Hepatobiliary Pancreat Dis Int, 2015, 14(1):34-42. doi: 10.1016/S1499-3872(15)60332-0 [7] REICH DJ, MULLIGAN DC, ABT PL, et al. ASTS recommended practice guidelines for controlled donation after cardiac death organ procurement and transplantation[J]. Am J Transplant, 2009, 9(9):2004-2011. DOI: 10.1111/j.1600-6143.2009.02739.x. [8] BERNAT JL, D'ALESSANDRO AM, PORT FK, et al. Report of a national conference on donation after cardiac death[J]. Am J Transplant, 2006, 6(2):281-291. doi: 10.1111/j.1600-6143.2005.01194.x [9] 周智华, 朱有华, 牛强, 等.川芎嗪改善高渗枸橼酸盐嘌呤溶液保存犬肾的效果[J].中华器官移植杂志, 2006, 27(7):411-413.DOI: 10.3760/cma.j.issn.0254-1785.2006.07.007.ZHOU ZH, ZHU YH, NIU Q, et al. Effect of ligustrazine on canine kidney preservation with hypertonic citrate adenine solution[J]. Chin J Organ Transplant, 2006, 27(7):411-413. DOI:10.3760/cma.j.issn. 0254-1785.2006.07.007. [10] 袁清, 赵闻雨, 熊海云, 等.自制新型多器官保存液低温保存小型猪肾[J].中国组织工程研究与临床康复, 2009, 13(18):3467-3470.DOI: 10.3969/j.issn.1673-8225.2009.18.015.YUAN Q, ZHAO WY, XIONG HY, et al. Cryopreservation of mini pig kidney with the self-designed new multi-organ preservation solution[J]. Chin J Clin Rehabil Tissue Eng Res, 2009, 13(18):3467-3470. DOI: 10.3969/j.issn.1673-8225.2009.18.015. [11] HAMAR M, SELZNER M. Ex-vivo machine perfusion for kidney preservation[J]. Curr Opin Organ Transplant, 2018, 23(3):369-374. DOI: 10.1097/MOT.0000000000000524. [12] GUARRERA JV, POLYAK M, O'MAR ARRINGTON B, et al. Pulsatile machine perfusion with Vasosol solution improves early graft function after cadaveric renal transplantation[J]. Transplantation, 2004, 77(8):1264-1268. doi: 10.1097/01.TP.0000122221.28546.6D [13] HOSGOOD SA, NICHOLSON ML. The first clinical case of intermediate ex vivo normothermic perfusion in renal transplantation[J]. Am J Transplant, 2014, 14(7):1690-1692. DOI: 10.1111/ajt.12766. [14] BAGUL A, HOSGOOD SA, KAUSHIK M, et al. Experimental renal preservation by normothermic resuscitation perfusion with autologous blood[J]. Br J Surg, 2008, 95(1):111-118. http://d.old.wanfangdata.com.cn/NSTLQK/NSTL_QKJJ023054129/ [15] MIÑAMBRES E, SUBERVIOLA B, DOMINGUEZ-GIL B, et al. Improving the outcomes of organs obtained from controlled donation after circulatory death donors using abdominal normothermic regional perfusion[J]. Am J Transplant, 2017, 17(8):2165-2172. DOI: 10.1111/ajt.14214. [16] PATEL K, NATH J, HODSON J, et al. Outcomes of donation after circulatory death kidneys undergoing hypothermic machine perfusion following static cold storage: a UK population-based cohort study[J]. Am J Transplant, 2018, 18(6):1408-1414. DOI: 10.1111/ajt.14587. [17] 中华医学会器官移植学分会.尸体供肾体外机械灌注冷保存技术操作规范(2019版)[J].器官移植, 2019, 10(3):263-266.DOI: 10.3969/j.issn.1674-7445.2019.03.007.Branch of Organ Transplantation of Chinese Medical Association. Technical operation specification for the extracorporeal mechanical perfusion and cold preservation of the deceased donor kidney(2019 edition)[J]. Organ Transplant, 2019, 10(3): 263-266. DOI: 10.3969/j.issn.1674-7445.2019.03.007. [18] HOSGOOD SA, SAEB-PARSY K, HAMED MO, et al. Successful transplantation of human kidneys deemed untransplantable but resuscitated by ex vivo normothermic machine perfusion[J]. Am J Transplant, 2016, 16(11):3282-3285. DOI: 10.1111/ajt.13906. [19] DIRITO JR, HOSGOOD SA, TIETJEN GT, et al. The future of marginal kidney repair in the context of normothermic machine perfusion[J]. Am J Transplant, 2018, 18(10):2400-2408. DOI: 10.1111/ajt.14963. [20] PHILLIPS BL, CHANDAK P, UWECHUE R, et al.Microbial contamination during kidney ex vivo normothermic perfusion[J]. Transplantation, 2018, 102(4): e186-e188. DOI: 10.1097/TP.0000000000002076. [21] KATHS JM, ECHEVERRI J, LINARES I, et al. Normothermic ex vivo kidney perfusion following static cold storage-brief, intermediate, or prolonged perfusion for optimal renal graft reconditioning?[J]. Am J Transplant, 2017, 17(10):2580-2590. DOI: 10.1111/ajt.14294. [22] HAMEED AM, MIRAZIZ R, LU DB, et al. Extra-corporeal normothermic machine perfusion of the porcine kidney: working towards future utilization in Australasia[J]. ANZ J Surg, 2018, 88(5): E429-E434. DOI: 10.1111/ans.14321. [23] WEISSENBACHER A, LO FARO L, BOUBRIAK O, et al. Twenty-four-hour normothermic perfusion of discarded human kidneys with urine recirculation[J]. Am J Transplant, 2019, 19(1):178-192. DOI: 10.1111/ajt.14932. [24] HOSGOOD SA, SAEB-PARSY K, WILSON C, et al. Protocol of a randomised controlled, open-label trial of ex vivo normothermic perfusion versus static cold storage in donation after circulatory death renal transplantation[J]. BMJ Open, 2017, 7(1): e012237. DOI: 10.1136/bmjopen- 2016-012237. [25] ADAMS TD, PATEL M, HOSGOOD SA, et al. Lowering perfusate temperature from 37 ℃ to 32 ℃ diminishes function in a porcine model of ex vivo kidney perfusion[J]. Transplant Direct, 2017, 3(3): e140. DOI: 10.1097/TXD.0000000000000655. [26] HAMAR M, URBANELLIS P, KATHS MJ, et al. Normothermic ex vivo kidney perfusion reduces warm ischemic injury of porcine kidney grafts retrieved after circulatory death[J]. Transplantation, 2018, 102(8):1262-1270. DOI: 10.1097/TP.0000000000002245. [27] HOSGOOD SA, NICHOLSON ML. An assessment of urinary biomarkers in a series of declined human kidneys measured during ex vivo normothermic kidney perfusion[J]. Transplantation, 2017, 101(9):2120-2125. DOI: 10.1097/TP.0000000000001504. [28] HOYER DP, GALLINAT A, SWOBODA S, et al. Subnormothermic machine perfusion for preservation of porcine kidneys in a donation after circulatory death model[J]. Transpl Int, 2014, 27(10):1097-1106. DOI: 10.1111/tri.12389. [29] MINOR T, EFFERZ P, FOX M, et al. Controlled oxygenated rewarming of cold stored liver grafts by thermally graduated machine perfusion prior to reperfusion[J]. Am J Transplant, 2013, 13(6):1450-1460. DOI: 10.1111/ajt.12235. [30] MOLINA M, GUERRERO-RAMOS F, FERNÁNDEZ-RUIZ M, et al. Kidney transplant from uncontrolled donation after circulatory death donors maintained by nECMO has long-term outcomes comparable to standard criteria donation after brain death[J]. Am J Transplant, 2019, 19(2):434-447. DOI: 10.1111/ajt.14991. [31] 谭红梅.不同生长因子对常温下体外灌流兔肾影响的实验研究[D].重庆: 第三军医大学, 2005. http://cdmd.cnki.com.cn/Article/CDMD-90025-2006140751.htm [32] SIERRA-PARRAGA JM, EIJKEN M, HUNTER J, et al.Mesenchymal stromal cells as anti-inflammatory and regenerative mediators for donor kidneys during normothermic machine perfusion[J]. Stem Cells Dev, 2017, 26(16):1162-1170. DOI: 10.1089/scd.2017.0030. [33] WEISSENBACHER A, HUNTER J. Normothermic machine perfusion of the kidney[J]. Curr Opin Organ Transplant, 2017, 22(6):571-576. DOI: 10.1097/MOT. 0000000000000470. [34] YONG C, HOSGOOD SA, NICHOLSON ML. Ex-vivo normothermic perfusion in renal transplantation: past, present and future[J]. Curr Opin Organ Transplant, 2016, 21(3):301-307. DOI: 10.1097/MOT.0000000000000316. [35] BRAT A, POL RA, LEUVENINK HG. Novel preservation methods to increase the quality of older kidneys[J]. Curr Opin Organ Transplant, 2015, 20(4):438-443. DOI: 10.1097/MOT.0000000000000215.
点击查看大图
计量
- 文章访问数: 493
- HTML全文浏览量: 288
- PDF下载量: 125
- 被引次数: 0