Volume 12 Issue 5
Sep.  2021
Turn off MathJax
Article Contents
Xu Lin, Yan Haoji, Wang Junjie, et al. Current status and prospect of imaging examination methods for rejection after lung transplantation[J]. ORGAN TRANSPLANTATION, 2021, 12(5): 544-549. doi: 10.3969/j.issn.1674-7445.2021.05.007
Citation: Xu Lin, Yan Haoji, Wang Junjie, et al. Current status and prospect of imaging examination methods for rejection after lung transplantation[J]. ORGAN TRANSPLANTATION, 2021, 12(5): 544-549. doi: 10.3969/j.issn.1674-7445.2021.05.007

Current status and prospect of imaging examination methods for rejection after lung transplantation

doi: 10.3969/j.issn.1674-7445.2021.05.007
More Information
  • Corresponding author: Tian Dong, E-mail: TianD_EATTS@nsmc.edu.cn
  • Received Date: 2021-06-30
    Available Online: 2021-09-15
  • Publish Date: 2021-09-15
  • Lung transplantation is the only effective therapeutic option for end-stage lung diseases, and postoperative rejection is the main factor affecting clinical prognosis of the recipients. Imaging examination can be utilized as a noninvasive tool to assist other examinations in monitoring rejection after lung transplantation. At present, multiple imaging examination methods have been reported. The advantages and disadvantages of various imaging examinations have been clarified, which may promote early diagnosis of rejection, deliver timely treatment for lung transplant recipients and improve the quality of life and clinical prognosis. In this article, the advantages, disadvantages and research progress upon different imaging examinations for rejection after lung transplantation were reviewed, aiming to provide reference for identifying the optimal noninvasive examination approach for rejection after lung transplantation and enhance the long-term survival of the recipients.

     

  • loading
  • [1]
    ARYAL S, NATHAN SD. Lung transplantation in China: a firm foundation for a solid future[J]. Ann Transl Med, 2020, 8(6): 265. DOI: 10.21037/atm.2020.02.165.
    [2]
    胡春晓, 李小杉, 卫栋, 等. 前进中的肺移植事业——我国肺移植发展现状及未来[J]. 器官移植, 2020, 11(2): 204-207. DOI: 10.3969/j.issn.1674-7445.2020.02.005.

    HU CX, LI XS, WEI D, et al. The development of lung transplantation: current situation and future of lung transplantation in China[J]. Organ Transplant, 2020, 11(2): 204-207. DOI: 10.3969/j.issn.1674-7445. 2020.02.005.
    [3]
    KHUSH KK, CHERIKH WS, CHAMBERS DC, et al. The International Thoracic Organ Transplant Registry of the International Society for Heart and Lung Transplantation: thirty-sixth adult heart transplantation report - 2019; focus theme: donor and recipient size match[J]. J Heart Lung Transplant, 2019, 38(10): 1056-1066. DOI: 10.1016/j.healun.2019.08.004.
    [4]
    TIAN D, HUANG H, WEN HY. Noninvasive methods for detection of chronic lung allograft dysfunction in lung transplantation[J]. Transplant Rev (Orlando), 2020, 34(3): 100547. DOI: 10.1016/j.trre.2020.100547.
    [5]
    Branch of Organ Transplantation of Chinese Medical Association. Diagnosis and treatment specification for immunosuppressive therapy and rejection in lung transplantation in China (2019 edition)[J/CD]. Chin J Transplant (Electr Edit), 2019, 13(2): 94-98. DOI: 10.3877/cma.j.issn.1674-3903.2019.02.004.
    [6]
    GREER M, WERLEIN C, JONIGK D. Surveillance for acute cellular rejection after lung transplantation[J]. Ann Transl Med, 2020, 8(6): 410. DOI: 10.21037/atm.2020.02.127.
    [7]
    PARULEKAR AD, KAO CC. Detection, classification, and management of rejection after lung transplantation[J]. J Thorac Dis, 2019, 11(Suppl 14): S1732-S1739. DOI: 10.21037/jtd.2019.03.83.
    [8]
    BERGIN CJ, CASTELLINO RA, BLANK N, et al. Acute lung rejection after heart-lung transplantation: correlation of findings on chest radiographs with lung biopsy results[J]. AJR Am J Roentgenol, 1990, 155(1): 23-27. DOI: 10.2214/ajr.155.1.2112858.
    [9]
    KUNDU S, HERMAN SJ, LARHS A, et al. Correlation of chest radiographic findings with biopsy-proven acute lung rejection[J]. J Thorac Imaging, 1999, 14(3): 178-184. DOI: 10.1097/00005382-199907000-00004.
    [10]
    PARK CH, PAIK HC, HAAM SJ, et al. HRCT features of acute rejection in patients with bilateral lung transplantation: the usefulness of lesion distribution[J]. Transplant Proc, 2014, 46(5): 1511-1516. DOI: 10.1016/j.transproceed.2013.12.060.
    [11]
    GOTWAY MB, DAWN SK, SELLAMI D, et al. Acute rejection following lung transplantation: limitations in accuracy of thin-section CT for diagnosis[J]. Radiology, 2001, 221(1): 207-212. DOI: 10.1148/radiol.2211010380.
    [12]
    DI PIAZZA A, MAMONE G, CARUSO S, et al. Acute rejection after lung transplantation: association between histopathological and CT findings[J]. Radiol Med, 2019, 124(10): 1000-1005. DOI: 10.1007/s11547-019-01059-z.
    [13]
    HORIE M, LEVY L, HOUBOIS C, et al. Lung density analysis using quantitative chest CT for early prediction of chronic lung allograft dysfunction[J]. Transplantation, 2019, 103(12): 2645-2653. DOI: 10.1097/TP.0000000000002771.
    [14]
    DETTMER S, SUHLING H, KLINGENBERG I, et al. Lobe-wise assessment of lung volume and density distribution in lung transplant patients and value for early detection of bronchiolitis obliterans syndrome[J]. Eur J Radiol, 2018, 106: 137-144. DOI: 10.1016/j.ejrad.2018.07.016.
    [15]
    DUBBELDAM A, BARTHELS C, COOLEN J, et al. Restrictive allograft syndrome after lung transplantation: new radiological insights[J]. Eur Radiol, 2017, 27(7): 2810-2817. DOI: 10.1007/s00330-016-4643-5.
    [16]
    HABRE C, SOCCAL PM, TRIPONEZ F, et al. Radiological findings of complications after lung transplantation[J]. Insights Imaging, 2018, 9(5): 709-719. DOI: 10.1007/s13244-018-0647-9.
    [17]
    PHILIPPOT Q, DEBRAY MP, BUN R, et al. Use of CT-scan score and volume measures to early identify restrictive allograft syndrome in single lung transplant recipients[J]. J Heart Lung Transplant, 2020, 39(2): 125-133. DOI: 10.1016/j.healun.2019.11.008.
    [18]
    BARBOSA EJM JR, LANCLUS M, VOS W, et al. Machine learning algorithms utilizing quantitative CT features may predict eventual onset of bronchiolitis obliterans syndrome after lung transplantation[J]. Acad Radiol, 2018, 25(9): 1201-1212. DOI: 10.1016/j.acra. 2018.01.013.
    [19]
    GUO J, HUANG HJ, WANG X, et al. Imaging mouse lung allograft rejection with (1)H MRI[J]. Magn Reson Med, 2015, 73(5): 1970-1978. DOI: 10.1002/mrm.25313.
    [20]
    KANNO S, LEE PC, DODD SJ, et al. A novel approach with magnetic resonance imaging used for the detection of lung allograft rejection[J]. J Thorac Cardiovasc Surg, 2000, 120(5): 923-934. DOI: 10.1067/mtc.2000.110184.
    [21]
    CHUCK NC, BOSS A, WURNIG MC, et al. Ultra-short echo-time magnetic resonance imaging distinguishes ischemia/reperfusion injury from acute rejection in a mouse lung transplantation model[J]. Transpl Int, 2016, 29(1): 108-118. DOI: 10.1111/tri.12680.
    [22]
    EULER A, BLÜTHGEN C, WURNIG MC, et al. Can texture analysis in ultrashort echo-time MRI distinguish primary graft dysfunction from acute rejection in lung transplants? a multidimensional assessment in a mouse model[J]. J Magn Reson Imaging, 2020, 51(1): 108-116. DOI: 10.1002/jmri.26817.
    [23]
    MOHER ALSADY T, VOSKREBENZEV A, GREER M, et al. MRI-derived regional flow-volume loop parameters detect early-stage chronic lung allograft dysfunction[J]. J Magn Reson Imaging, 2019, 50(6): 1873-1882. DOI: 10.1002/jmri.26799.
    [24]
    MOUTAFIDIS D, GAVRA M, GOLFINOPOULOS S, et al. Lung hyperinflation quantitated by chest CT in children with bronchiolitis obliterans syndrome following allogeneic hematopoietic cell transplantation[J]. Clin Imaging, 2021, 75: 97-104. DOI: 10.1016/j.clinimag. 2021.01.011.
    [25]
    VOSKREBENZEV A, GREER M, GUTBERLET M, et al. Detection of chronic lung allograft dysfunction using ventilation-weighted Fourier decomposition MRI[J]. Am J Transplant, 2018, 18(8): 2050-2060. DOI: 10.1111/ajt.14759.
    [26]
    PENNATI F, SALITO C, BORZANI I, et al. Quantitative multivolume proton-magnetic resonance imaging in lung transplant recipients: comparison with computed tomography and spirometry[J]. Acad Radiol, 2020, DOI: 10.1016/j.acra.2020.05.026[Epubahead of print].
    [27]
    钱根年. 分子影像设备PET/CT成像系统的技术进展[J/CD]. 功能与分子医学影像学杂志(电子版), 2019, 8(1): 1579-1582. DOI: 10.3969/j.issn.2095-2252.2019.01.001.

    QIAN GN. Technical progress of molecular imaging equipment PET/CT imaging system[J/CD]. Funct Mol Med Imaging (Electr Edit), 2019, 8(1): 1579-1582. DOI: 10.3969/j.issn.2095-2252.2019.01.001.
    [28]
    ERTAY T, SENCAN EREN M, KARAMAN M, et al. 18F-FDG-PET/CT in initiation and progression of inflammation and infection[J]. Mol Imaging Radionucl Ther, 2017, 26(2): 47-52. DOI: 10.4274/mirt.18291.
    [29]
    CHEN DL, CHERIYAN J, CHILVERS ER, et al. Quantification of lung PET images: challenges and opportunities[J]. J Nucl Med, 2017, 58(2): 201-207. DOI: 10.2967/jnumed.116.184796.
    [30]
    CHEN DL, WANG X, YAMAMOTO S, et al. Increased T cell glucose uptake reflects acute rejection in lung grafts[J]. Am J Transplant, 2013, 13(10): 2540-2549. DOI: 10.1111/ajt.12389.
    [31]
    VERLEDEN SE, GHEYSENS O, GOFFIN KE, et al. Role of 18F-FDG PET/CT in restrictive allograft syndrome after lung transplantation[J]. Transplantation, 2019, 103(4): 823-831. DOI: 10.1097/TP.0000000000002393.
    [32]
    ZHENG B, MAEHARA A, MINTZ GS, et al. Increased coronary lipid accumulation in heart transplant recipients with prior high-grade cellular rejection: novel insights from near-infrared spectroscopy[J]. Int J Cardiovasc Imaging, 2016, 32(2): 225-234. DOI: 10.1007/s10554-015-0777-9.
    [33]
    BENSTED K, MCKENZIE J, HAVRYK A, et al. Lung ultrasound after transbronchial biopsy for pneumothorax screening in post-lung transplant patients[J]. J Bronchol Interv Pulmonol, 2018, 25(1): 42-47. DOI: 10.1097/LBR.0000000000000446.
    [34]
    DIANA P, ZAMPIERI D, FURLANI E, et al. Lung ultrasound as a monitoring tool in lung transplantation in rodents: a feasibility study[J]. J Thorac Dis, 2018, 10(7): 4274-4282. DOI: 10.21037/jtd.2018.06.52.
    [35]
    NARULA T, BANGA A, SAHOO D, et al. Lung ultrasound to detect allograft dysfunction in lung transplant recipients[J]. Am J Respir Crit Care Med, 2019, 199: A2886.
    [36]
    DAVIDSEN JR, LAURSEN CB, BENDSTRUP E, et al. Lung ultrasound - a novel diagnostic tool to phenotype chronic lung allograft dysfunction?[J]. Ultrasound Int Open, 2017, 3(3): E117-E119. DOI: 10.1055/s-0043-116489.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(1)  / Tables(1)

    Article Metrics

    Article views (438) PDF downloads(94) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return